SILVER AUTOMATION INSTRUMENTS LTD.
PRODUCT_CATEGORY

Theo Media
Đồng hồ đo lưu lượng

Yêu cầu lắp đặt đồng hồ đo mức radar 26G

Chuẩn bị trước khi cài đặt
Những điểm sau đây cần được chú ý:
- Không gian cần phải được bảo lưu
- Tránh không gian rung mạnh
- Cần tuân thủ các yêu cầu cài đặt
* Hướng dẫn cài đặt:
Máy đo mức radar phải được lắp đặt trong đường kính 1/4 hoặc 1/6 của bể chứa; tối thiểu khoảng cách cần thiết giữa máy đo mức radar và thành tàu là 250mm


▶ Installation Instruction:The radar level meter should be installed in the 1/4 or 1/6 of diameter of the storage tank; min. distance required between the radar level meter and vessel wall is 250mm

26g-radar-level-meter1





①Reference Plane

②Center of Vessel or Symmetrical axis

▶ The best mounting position for a conical vessel with flat top is the center of its top, as the effective measurement can reach the bottom of vessel.

26g-radar-level-meter2

▶ Storage tank with stockpile: TheAntenna should be vertical to the stockpile, if the stockpile is noteven; gimbal is required to adjust the hornantenna.

storage-tank1

l Typical wrong installation:

▶ the radar should not be installed in the feed port, also the radar is better to be free from rain and sunshine.

storage-tank2





①Correct

②Wrong



▶ Theradar level meter should not be installed in the center of arch tank , if installed in the center, it will result in multiple echoes and affect the measuring effect.

the-radar-level-meter




①Correct

②Wrong


▶ If there are obstacles in the tank which can affect the measuring result, reflector is required.

the-radar-level-meter2





①Correct

②Wrong



▶ If there is obstacle it the areawhere the microwave covers, such as ladder, limit switch, heating devices, support .etc which will lead to a wrong measuring, wave guide is required.


▶ If there are obstacles in the tank which can affect the measuring result, reflector is required.

Note: the diameter of ventilation hole is 5~10mm.

The diameter of wave guide is minimum 50mm, and the internal of the pipe should be smooth.

Suitable for liquids with good fluidity, not good for viscous liquids.



▶ Connection Pipe requirement:Antenna minimum length into tank is 10mm